A Web-Based Clinical Decision-Support Dashboard for Glaucoma Screening from Retinal Fundus Images: A Two-Phase VGG16 Deep Learning Pipeline with Grad-CAM Interpretability for Ophthalmology Practice

Authors

  • Shafiya Qadeer Memon Mehran University of Engineering & Technology Jamshoro
  • Rafay Shakeel Mehran University of Engineering and Technology, Jamshoro 76062, Sindh, Pakistan
  • Sachal Sahito Department of Software Engineering, Mehran UET Jamshoro
  • Areeba Syed Department of Software Engineering, Mehran UET Jamshoro
  • Mehran Memon Sindh Institute of Ophthalmology and Visual Sciences (SIOVS) Hyderabad Pakistan
  • Amirita Dewani Mehran University of Engineering and Technology, Jamshoro 76062, Sindh, Pakistan

DOI:

https://doi.org/10.33411/IJIST/2015

Keywords:

Glaucoma, Deep learning, Convolutional neural network, Transfer learning, Fundus imaging, Grad-CAM

Abstract

Objective: To develop and evaluate a two-phase transfer-learning pipeline using a VGG16 convolutional neural network for automated binary classification of glaucoma from retinal fundus images, designed for deployment in resource-constrained South Asian screening contexts.

Methods: A retrospective diagnostic-accuracy study used 705 retinal fundus images from the public ACRIMA dataset. The model employed a VGG16 backbone pre-trained on ImageNet with a custom classification head (global average pooling, two dense ReLU layers with dropout, sigmoid output).  Phase-1 trained the head with the backbone frozen (Adam, lr 1 × 10−4, 50 epochs). Phase-2 unfroze the last four convolutional block and fine-tuned at lr 1×10−5 for 25 epochs. Online augmentation, inverse-frequency class weighting, early stopping and learning-rate reduction on plateau were applied. A held-out test set (n = 140, balanced 70/70) was used for final evaluation. A FastAPI inference service and a Next.js clinical dashboard were developed for clinician-facing deployment.

Results: The fine-tuned network achieved accuracy 88.57% (95% CI: 82.2–92.8%), sensitivity 92.86% (95% CI: 84.3–96.9%), specificity 84.29% (95% CI: 74.0–91.0%), precision 85.53% (95% CI: 75.9–91.7%), F1-score 89.04%, and AUC-ROC 0.954 (95% CI: 0.918–0.990). Phase-2 fine-tuning raised sensitivity by 7.15 percentage points over Phase-1 (85.71% → 92.86%) and reduced the false-negative rate from 14.3% to 7.1%. Grad-CAM heatmaps consistently localized activation over the optic disc and peripapillary region.

Conclusion: A computationally tractable, interpretable VGG16 pipeline reached screening-level sensitivity with a clinician-facing dashboard, providing a reproducible foundation for region-adapted glaucoma screening pending prospective validation on a Pakistani cohort.

References

Y. C. Tham, X. Li, T. Y. Wong, H. A. Quigley, T. Aung, and C. Y. Cheng, “Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis,” Ophthalmology, vol. 121, no. 11, pp. 2081–2090, Nov. 2014, doi: 10.1016/j.ophtha.2014.05.013.

M. S. M. Zahid Hussain Awan, P.S. Mahar, “Blindness and Poverty,” Pak J Ophthalmol, vol. 27, no. 3, pp. 165–170, Nov. 2011, Accessed: Aug. 25, 2026. [Online]. Available: https://pjo.org.pk/index.php/pjo/article/view/489/418

“WHO Releases World Report on Vision.” Accessed: Aug. 25, 2026. [Online]. Available: https://cureblindness.org/news/who-releases-world-report-on-vision?utm_source=google&utm_medium=cpc&utm_campaign=dynamic-grant&utm_id=10038769322&utm_term=&utm_content=730060842429&utm_source_platform=google-ads&utm_creative_format=text&utm_marketing_tactic=acquisition&c_src=WEB0126GG&gad_source=1&gad_campaignid=10038769322&gbraid=0AAAAADr1f9Wi1U4QYqJFcN-5q2tIIgHML&gclid=CjwKCAjw-rTUBhAiEiwADv8gBD60c7fknw2kVB0Qx0-cZZW1HEy3il1nXcs9NHu4_0-5ZrAEUilMqxoClT0QAvD_BwE

R. N. Weinreb, T. Aung, and F. A. Medeiros, “The pathophysiology and treatment of glaucoma: a review,” JAMA, vol. 311, no. 18, pp. 1901–1911, May 2014, doi: 10.1001/JAMA.2014.3192.

“Glaucoma: What It Is, Symptoms, Causes, Types & Treatment.” Accessed: Aug. 25, 2026. [Online]. Available: https://my.clevelandclinic.org/health/diseases/4212-glaucoma

D. S. W. Ting et al., “Artificial intelligence and deep learning in ophthalmology,” Br. J. Ophthalmol., vol. 103, no. 2, pp. 167–175, Feb. 2019, doi: 10.1136/BJOPHTHALMOL-2018-313173.

Z. Li, Y. He, S. Keel, W. Meng, R. T. Chang, and M. He, “Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs,” Ophthalmology, vol. 125, no. 8, pp. 1199–1206, Aug. 2018, doi: 10.1016/j.ophtha.2018.01.023.

A. Diaz-Pinto, S. Morales, V. Naranjo, T. Köhler, J. M. Mossi, and A. Navea, “CNNs for automatic glaucoma assessment using fundus images: an extensive validation,” Biomed. Eng. OnLine 2019 181, vol. 18, no. 1, pp. 29-, Mar. 2019, doi: 10.1186/S12938-019-0649-Y.

J. I. Orlando et al., “REFUGE Challenge: A unified framework for evaluating automated methods for glaucoma assessment from fundus photographs,” Med. Image Anal., vol. 59, p. 101570, Jan. 2020, doi: 10.1016/J.MEDIA.2019.101570.

H. Fu et al., “Disc-Aware Ensemble Network for Glaucoma Screening from Fundus Image,” IEEE Trans. Med. Imaging, vol. 37, no. 11, pp. 2493–2501, Nov. 2018, doi: 10.1109/TMI.2018.2837012.

M. N. Bajwa et al., “Two-stage framework for optic disc localization and glaucoma classification in retinal fundus images using deep learning,” BMC Med. Inform. Decis. Mak., vol. 19, no. 1, Jul. 2019, doi: 10.1186/S12911-019-0842-8.

U. Raghavendra, H. Fujita, S. V. Bhandary, A. Gudigar, J. H. Tan, and U. R. Acharya, “Deep convolution neural network for accurate diagnosis of glaucoma using digital fundus images,” Inf. Sci. (Ny)., vol. 441, pp. 41–49, May 2018, doi: 10.1016/J.INS.2018.01.051.

S. Phene et al., “Deep Learning and Glaucoma Specialists: The Relative Importance of Optic Disc Features to Predict Glaucoma Referral in Fundus Photographs,” Ophthalmology, vol. 126, no. 12, pp. 1627–1639, Dec. 2019, doi: 10.1016/j.ophtha.2019.07.024.

R. Hemelings et al., “Accurate prediction of glaucoma from colour fundus images with a convolutional neural network that relies on active and transfer learning,” Acta Ophthalmol., vol. 98, no. 1, pp. e94–e100, Feb. 2020, doi: 10.1111/AOS.14193.

J. J. Gómez-Valverde et al., “Automatic glaucoma classification using color fundus images based on convolutional neural networks and transfer learning,” Biomed. Opt. Express, vol. 10, no. 2, p. 892, Feb. 2019, doi: 10.1364/BOE.10.000892.

N. Shibata et al., “Development of a deep residual learning algorithm to screen for glaucoma from fundus photography,” Sci. Reports 2018 81, vol. 8, no. 1, pp. 14665-, Oct. 2018, doi: 10.1038/s41598-018-33013-w.

J. M. Ahn, S. Kim, K. S. Ahn, S. H. Cho, K. B. Lee, and U. S. Kim, “A deep learning model for the detection of both advanced and early glaucoma using fundus photography,” PLoS One, vol. 13, no. 11, p. e0207982, Nov. 2018, doi: 10.1371/JOURNAL.PONE.0207982.

R. Asaoka et al., “Using Deep Learning and Transfer Learning to Accurately Diagnose Early-Onset Glaucoma From Macular Optical Coherence Tomography Images,” Am. J. Ophthalmol., vol. 198, pp. 136–145, Feb. 2019, doi: 10.1016/j.ajo.2018.10.007.

M. Christopher et al., “Performance of Deep Learning Architectures and Transfer Learning for Detecting Glaucomatous Optic Neuropathy in Fundus Photographs,” Sci. Reports 2018 81, vol. 8, no. 1, pp. 16685-, Nov. 2018, doi: 10.1038/s41598-018-35044-9.

A. Serener and S. Serte, “Transfer learning for early and advanced glaucoma detection with convolutional neural networks,” TIPTEKNO 2019 - Tip Teknol. Kongresi, Oct. 2019, doi: 10.1109/TIPTEKNO.2019.8894965.

S. Sreng, N. Maneerat, K. Hamamoto, and K. Y. Win, “Deep Learning for Optic Disc Segmentation and Glaucoma Diagnosis on Retinal Images,” Appl. Sci. 2020, Vol. 10, Page 4916, vol. 10, no. 14, p. 4916, Jul. 2020, doi: 10.3390/APP10144916.

P. Elangovan and M. K. Nath, “Glaucoma assessment from color fundus images using convolutional neural network,” Int. J. Imaging Syst. Technol., vol. 31, no. 2, pp. 955–971, Jun. 2021, doi: 10.1002/IMA.22494;CTYPE:STRING:JOURNAL.

M. Nawaz et al., “An Efficient Deep Learning Approach to Automatic Glaucoma Detection Using Optic Disc and Optic Cup Localization,” Sensors 2022, Vol. 22, Page 434, vol. 22, no. 2, p. 434, Jan. 2022, doi: 10.3390/S22020434.

Ramprasaath R. Selvaraju, Michael Cogswell, Abhishek Das, Ramakrishna Vedantam, Devi Parikh, Dhruv Batra, “Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localization,” Int. J. Comput. Vis., 2016, [Online]. Available: https://arxiv.org/abs/1610.02391

Karen Simonyan, Andrew Zisserman, “Very Deep Convolutional Networks for Large-Scale Image Recognition,” arXiv:1409.1556, 2015, [Online]. Available: https://arxiv.org/abs/1409.1556

A. Shoukat, S. Akbar, S. A. Hassan, S. Iqbal, A. Mehmood, and Q. M. Ilyas, “Automatic Diagnosis of Glaucoma from Retinal Images Using Deep Learning Approach,” Diagnostics (Basel, Switzerland), vol. 13, no. 10, May 2023, doi: 10.3390/DIAGNOSTICS13101738.

Y. Y. Chiang, C. L. Chen, and Y. H. Chen, “Deep Learning Evaluation of Glaucoma Detection Using Fundus Photographs in Highly Myopic Populations,” Biomedicines, vol. 12, no. 7, p. 1394, Jul. 2024, doi: 10.3390/BIOMEDICINES12071394/S1.

B. Chuter et al., “Deep Learning Identifies High-Quality Fundus Photographs and Increases Accuracy in Automated Primary Open Angle Glaucoma Detection,” Transl. Vis. Sci. Technol., vol. 13, no. 1, Jan. 2024, doi: 10.1167/TVST.13.1.23.

X. C. Ling et al., “Deep Learning in Glaucoma Detection and Progression Prediction: A Systematic Review and Meta-Analysis,” Biomedicines, vol. 13, no. 2, p. 420, Feb. 2025, doi: 10.3390/BIOMEDICINES13020420/S1.

Y. Jin, L. Liang, J. Li, K. Xu, W. Zhou, and Y. Li, “Artificial intelligence and glaucoma: a lucid and comprehensive review,” Front. Med., vol. 11, 2024, doi: 10.3389/FMED.2024.1423813.

Y. Hagiwara, O.-A. Ciora, M. Monnet, G. Lancho, and J. M. Lorenz, “AI-Driven Approaches for Glaucoma Detection -- A Comprehensive Review,” Oct. 2024, Accessed: Aug. 25, 2026. [Online]. Available: https://arxiv.org/pdf/2410.15947

Downloads

Published

2026-09-08
CITATION
Published: 2026-09-08
Crossref Citation Count: Loading...

How to Cite

Memon, S. Q., Shakeel, R., Sahito, S., Syed, A., Memon, M., & Dewani, A. (2026). A Web-Based Clinical Decision-Support Dashboard for Glaucoma Screening from Retinal Fundus Images: A Two-Phase VGG16 Deep Learning Pipeline with Grad-CAM Interpretability for Ophthalmology Practice. International Journal of Innovations in Science & Technology, 8(6), 2452–2467. https://doi.org/10.33411/IJIST/2015